Reliability, validity, usefulness, and sensitivity of a submaximal test of performing burpees in 3 minutes, in assessing and detecting changes in aerobic fitness of athletes during future prolonged self-isolation in a confined environment
(Zuverlässigkeit, Validität, Nützlichkeit und Sensitivität eines submaximalen Tests zur Durchführung von Burpees in 3 Minuten zur Bewertung und Erkennung von Veränderungen der aeroben Fitness von Athleten während zukünftiger längerer Selbstisolierung in einer eingeschränkten Umgebung)
BACKGROUND: During a prolonged quarantine, there is a need to monitor aerobic fitness levels of trained individuals who are isolated with a simple fitness test that can be performed in confined space of their own homes. This study examined the reliability, validity, usefulness and sensitivity of a novel 3-min submaximal heart rate burpees test (or SubHR3-MBT) to assess and monitor changes in aerobic fitness, of trained athletes. In the SubHR3-MBT, male and female athletes performed 48 and 39 burpees respectively, within 3 min by following a constant beeping pace. The performance criterion of the SubHR3-MBT is the highest heart rate attained (or exercise HRpeak) at the end of 3-min (wherein a lower exercise HRpeak indicates a higher level of aerobic fitness).
METHODS: A total of 40 male and female national athletes from various sports volunteered for the study.
RESULTS: For reliability (Part 1), the SubHR3-MBT showed good relative and excellent reliability, with intraclass correlation coefficient 0.90 and coefficient of variation 2.6%, respectively. For validity (Part II), there was significant negative correlation between relative exercise HRpeak with respiratory gas-measured VO2max (r=-0.51, large; P<0.001). The test`s technical error of measurement of 2.3 is slightly greater than its smallest worthwhile change of 1.5. For sensitivity (Part III), the athletes were tested twice for their SubHR3-MBT and VO2max, once at baseline and another at a followed-up test after >10 weeks. There was a significant correlation between the % change in relative exercise HRpeak with the % change in VO2max (r=-0.66, large; P<0.001).
CONCLUSIONS: The SubHR3-MBT is a reliable, valid, marginally useful test and may be able to track changes in aerobic fitness in trained athletes with moderate levels of sensitivity, in case of future isolation due to pandemic occurrence.
© Copyright 2024 The Journal of Sports Medicine and Physical Fitness. Edizioni Minerva Medica. Alle Rechte vorbehalten.
| Schlagworte: | |
|---|---|
| Notationen: | Biowissenschaften und Sportmedizin Trainingswissenschaft |
| Tagging: | COVID-19 Reliabilität Validität |
| Veröffentlicht in: | The Journal of Sports Medicine and Physical Fitness |
| Sprache: | Englisch |
| Veröffentlicht: |
2024
|
| Online-Zugang: | https://doi.org/10.23736/S0022-4707.24.15653-8 |
| Jahrgang: | 64 |
| Heft: | 7 |
| Seiten: | 631-639 |
| Dokumentenarten: | Artikel |
| Level: | hoch |