Changes of Achilles midportion tendon microcirculation after repetitive simultaneous cryotherapy and compression using a Cryo/Cuff
(Veränderungen der Mikrozirkulation des Mittelteiles der Achillessehne nach wiederholter gleichzeitiger Kryotherapie und Kompresssion mit einer Kryo-Manschette)
Cryotherapy and compression have been shown to decrease pain and improve function. The dosage and timing of these options remain unclear.
Purpose: To examine the effects of a standardized compression and cryotherapy device (Cryo/Cuff) on midportion Achilles tendon microcirculation during intermittent administration.
Study Design: Descriptive laboratory study.
Methods: Twenty-six subjects were included (13 men and 13 women; age, 32.3 ± 12 years; body mass index, 25.4 ± 5 kg/m2). Each underwent three 10-minute applications of the device, followed by a 10-minute recovery period. A continuous real-time assessment of parameters of Achilles tendon midportion microcirculation was performed with a laser Doppler spectrophotometry system.
Results: Superficial tendon oxygen saturation dropped significantly from 35.9 ± 21 arbitrary units (AU) to 13.5 ± 15, 15.9 ± 16, and 11.1 ± 11 AU (P = .0001) during each period of cryo-compression, respectively. There was significant increase during the recovery period (55.4 ± 29, 65.2 ± 26, and 65.7 ± 27 AU; P = .003), up to +83% of the baseline level. At 8-mm tendon depth, cryo-compression preserved local oxygen with -4% (P = .001) of the baseline level and small but significant increased oxygen saturation of up to +13% (P = .0001). Relative postcapillary venous tendon filling pressures were favorably reduced both superficially (57% ± 34%, 67% ± 27%, and 64% ± 38%, respectively; P = .0004) and deep (76% ± 13%, 79% ± 11%, and 78% ± 18%, respectively; P = .0002). Superficial capillary blood flow was reduced from 48.4 ± 48 to 5 ± 7, 4 ± 5, and 3 ± 4 AU at each period, respectively (-94%, P = .0003), with increased flow during recovery periods of up to 58 ± 64, 58 ± 79, and 47 ± 71 AU, respectively (+20%, P = .265). Deep flow was reduced from 197 ± 147 to 66.7 ± 64, 55 ± 46, and 43 ± 39 AU, respectively (-78%, P = .0002) without increase during recovery periods.
Conclusion: Cryo/Cuff exerts beneficial effects on the microcirculatory level of the midportion Achilles tendon with decreased capillary blood flow, preserved deep tendon oxygen saturation, and facilitated venous capillary outflow.
© Copyright 2006 The American Journal of Sports Medicine. SAGE Publications. Alle Rechte vorbehalten.
| Schlagworte: | |
|---|---|
| Notationen: | Biowissenschaften und Sportmedizin |
| Veröffentlicht in: | The American Journal of Sports Medicine |
| Sprache: | Englisch |
| Veröffentlicht: |
2006
|
| Online-Zugang: | https://doi.org/10.1177/0363546506293701 |
| Jahrgang: | 34 |
| Heft: | 12 |
| Seiten: | 1953-1959 |
| Dokumentenarten: | Artikel |
| Level: | hoch |