Sampling period determination for heart rate logging under an exercise regimen

(Aufzeichnungsrhythmus zur Bestimmung der Herzschlagfrequenz während unterschiedlicher Belastungen)

Using a mathematical procedure, we determine appropriate sampling rates for logging heart rate, at a variety of exercise intensities. The mathematical procedure involves correlating exercise and heart rate data to determine a dynamical mathematical model, from which the frequency response of the relationship between exercise intensity and heart rate can be determined. The sampling rate is then straightforwardly deduced by making appropriate measurements on the frequency response curve. We show how careful consideration needs to be given to the choice of dynamical model structure and the work regimen, so that consistent and convincing conclusions can be drawn. We demonstrate that the dynamics of the work-rate/heart-rate system are dependent on the nominal work/heart rate, but a 5-s sampling period, as used in many commercial heart rate monitors, appears to be adequate, especially when some averaging is performed before logging.
© Copyright 2006 Journal of Sports Sciences. Taylor & Francis. Alle Rechte vorbehalten.

Bibliographische Detailangaben
Schlagworte:
Notationen:Trainingswissenschaft Biowissenschaften und Sportmedizin Naturwissenschaften und Technik
Veröffentlicht in:Journal of Sports Sciences
Sprache:Englisch
Veröffentlicht: 2006
Online-Zugang:https://doi.org/10.1080/02640410500456978
Jahrgang:24
Heft:10
Seiten:1115-1125
Dokumentenarten:Artikel
Level:hoch