Reliability of near-infrared spectroscopy for determining muscle oxygen saturation during exercise

(Zuverlässigkeit der Infrarot-Spektroskopie zur Bestimmung der Sauerstoffsättigung im Muskel bei Belastung)

Near-infrared spectroscopy is currently used to assess changes in the oxygen saturation of the muscle during exercise. The primary purpose of this study was to assess the reliability of near-infrared spectroscopy in determining muscle oxygen saturation (StO2) in the vastus lateralis during cycling and the gastrocnemius during running for exercise intensities at lactate threshold and maximal effort. Test-retest reliability was determined from an intraclass correlation coefficient obtained from a one-way analysis of variance. Reliability of muscle StO2 for the gastrocnemius at lactate threshold was R = .87, and R = .88 at maximal effort. Reliability of muscle StO2 for the vastus lateralis at lactate threshold was R = .94 and R = .99 at maximal effort.
© Copyright 2005 Research Quarterly for Exercise and Sport. American Alliance for Health, Physical Education, Recreation and Dance (AAHPERD). Alle Rechte vorbehalten.

Bibliographische Detailangaben
Schlagworte:
Notationen:Ausdauersportarten
Veröffentlicht in:Research Quarterly for Exercise and Sport
Sprache:Englisch
Veröffentlicht: 2005
Jahrgang:76
Heft:4
Seiten:440-449
Dokumentenarten:Artikel
Level:mittel