4062722

Development of force plates installed with five-axis load cells and analysis using a wearable sensor system

(Entwicklung von Kraftmessplatten, die mit fünfachsigen Kraftmesszellen installiert sind, unter Einsatz eines tragbaren Sensorsystems)

In this study, we developed a new force plate system. Conventional force plates output force and moment by using the signals of three-axis load cells. The developed force plate installs four 5-axis load cells, and each load cell can output 3-axis force and 2-axis moment relating to deflection. The moment components of load cells are used for the compensation of cross talk and the calculation of moment in the force plate. The force plate can measure force and moment on the outside of load cells installed in the force plate. Gait measurement and analysis were conducted by using the developed force plate, a conventional force plate, and a wearable sensor system (wearable force plate). The results of the comparison of the developed force plates and the conventional force plate outputs indicated a difference in performance on the outside of load cells.
© Copyright 2020 Proceedings. MDPI. Alle Rechte vorbehalten.

Bibliographische Detailangaben
Schlagworte:
Notationen:Naturwissenschaften und Technik
Tagging:Kraftplattform
Veröffentlicht in:Proceedings
Sprache:Englisch
Veröffentlicht: 2020
Online-Zugang:https://doi.org/10.3390/proceedings2020049016
Jahrgang:49
Heft:1
Seiten:16
Dokumentenarten:Artikel
Level:hoch