Error reduction in the finite helical axis for knee kinematics

(Fehlerreduzierung in der Finite Helical Axis (FHA) für die Kniekinematik)

Traditionally the FHA is calculated stepwise between data points (sFHA), requiring down sampling to achieve a sufficiently large step size to minimize error. This paper proposes an alternate FHA calculation approach (rFHA), using a unique reference position to reduce error associated with small rotation angles. This study demonstrated error reduction using the rFHA approach relative to the sFHA approach. Furthermore, the rFHA in the femur is defined at each time point providing a continuous representation of joint motion. These characteristics enable the rFHA to quantify small differences in knee joint motion, providing an excellent measure to quantify knee joint stability.
© Copyright 2018 Computer Methods in Biomechanics and Biomedical Engineering. Taylor & Francis. Alle Rechte vorbehalten.

Bibliographische Detailangaben
Schlagworte:
Notationen:Naturwissenschaften und Technik
Veröffentlicht in:Computer Methods in Biomechanics and Biomedical Engineering
Sprache:Englisch
Veröffentlicht: 2018
Online-Zugang:https://doi.org/10.1080/10255842.2018.1435780
Jahrgang:21
Heft:2
Seiten:186-193
Dokumentenarten:Artikel
Level:hoch