Accuracy of an infrared LED device to measure heart rate and energy expenditure during rest and exercise
(Genauigkeit eines Infrarot-LED-Geräts zur Messung von Herzfrequenz und Energieverbrauch in Ruhe und unter Belastung)
The purpose of this study was to examine the accuracy of the ePulse Personal Fitness Assistant, a forearm-worn device that provides measures of heart rate and estimates energy expenditure. Forty-six participants engaged in 4-minute periods of standing, 2.0 mph walking, 3.5 mph walking, 4.5 mph jogging, and 6.0 mph running. Heart rate and energy expenditure were simultaneously recorded at 60-second intervals using the ePulse, an electrocardiogram (EKG), and indirect calorimetry. The heart rates obtained from the ePulse were highly correlated (intraclass correlation coefficients [ICCs] =0.85) with those from the EKG during all conditions. The typical errors progressively increased with increasing exercise intensity but were <5 bpm only during rest and 2.0 mph. Energy expenditure from the ePulse was poorly correlated with indirect calorimetry (ICCs: 0.01-0.36) and the typical errors for energy expenditure ranged from 0.69-2.97 kcal/min, progressively increasing with exercise intensity. These data suggest that the ePulse Personal Fitness Assistant is a valid device for monitoring heart rate at rest and low-intensity exercise, but becomes less accurate as exercise intensity increases. However, it does not appear to be a valid device to estimate energy expenditure during exercise.
© Copyright 2011 Journal of Sports Sciences. Taylor & Francis. Alle Rechte vorbehalten.
| Schlagworte: | |
|---|---|
| Notationen: | Trainingswissenschaft Naturwissenschaften und Technik |
| Veröffentlicht in: | Journal of Sports Sciences |
| Sprache: | Englisch |
| Veröffentlicht: |
2011
|
| Online-Zugang: | http://doi.org/10.1080/02640414.2011.609899 |
| Jahrgang: | 29 |
| Heft: | 15 |
| Seiten: | 1645-1653 |
| Dokumentenarten: | Artikel |
| Level: | mittel |