A re-appraisal of the reliability of the 20 m multi-stage shuttle run test

(Nochmalige Bewertung der Reliabilität des 20-m-Mehstufenpendellauftests)

Most studies that have set out to quantify the test-retest reliability of the multi-stage shuttle run test (MSSRT) have typically used inappropriate statistics (correlation coefficients) and/or one of two possible calculation methods for deriving predictions of maximal oxygen uptake $ (\ifmmode\expandafter\dot\else\expandafter\.\fi{V}{\text{O}}_{{2\max }} ), $Unknown control sequence '\ifmmode'and have not considered the impact of habituation on performance in the MSSRT and whether its reliability improves beyond a single repeat trial. In this context, the aim of this study was to assess the reliability of the MSSRT over three trials. Thirty-five healthy and active university games players (22 males and 13 females) performed the MSSRT on three occasions, 1 week apart. Individual total numbers of completed shuttles were recorded and estimated $ \ifmmode\expandafter\dot\else\expandafter\.\fi{V}{\text{O}}_{{2\max }} $Unknown control sequence '\ifmmode'values were derived via established equation and table methods. Analysis revealed that the overall mean $ \ifmmode\expandafter\dot\else\expandafter\.\fi{V}{\text{O}}_{{2\max }} $Unknown control sequence '\ifmmode'score from the equation method (52.5 ± 7.8 ml kg-1 min-1) was significantly higher than that for the table (46.9 ± 8.9 ml kg-1 min-1), whilst the mean trial 2 and trial 3 scores were significantly higher than that for trial 1, but not different to each other. The Limits of Agreement for the table method were -1.4 ± 5.0 (trial 1-trial 2) and 0.0 ± 5.5 ml kg-1 min-1 (trial 2-trial 3), and for the equation method -1.1 ± 4.7 (trial 1-trial 2) and 0.0 ± 5.0 ml kg-1 min-1 (trial 2-trial 3). These results suggest that systematic bias is eliminated after the first trial (due to habituation), but a considerable amount of random error remains, regardless of the type of score calculated. Hence, among our sample, the MSSRT does not appear to be reliable enough for the purpose of monitoring changes in $ \ifmmode\expandafter\dot\else\expandafter\.\fi{V}{\text{O}}_{{2\max }} $Unknown control sequence '\ifmmode'due to non-random reasons.
© Copyright 2007 European Journal of Applied Physiology. Springer. Alle Rechte vorbehalten.

Bibliographische Detailangaben
Schlagworte:
Notationen:Trainingswissenschaft
Veröffentlicht in:European Journal of Applied Physiology
Sprache:Englisch
Veröffentlicht: 2007
Online-Zugang:http://www.springerlink.com/content/f8t128h501324671/
Jahrgang:100
Heft:3
Seiten:253-260
Dokumentenarten:Artikel
Level:hoch