A new method for recording the temporal pattern of stride during treadmill running

(Eine neue Methode zur Aufzeichnung der zeitlichen Schrittmuster beim Laufen auf dem Laufband)

The aim of this study was to investigate the reliability of a new infrared light based method (IR40) for recording temporal stride patterns during treadmill running. The IR40 device, emitting a tight web of 40 infrared light beams 10 mm above the treadmill running surface, was compared to a previously validated electro-pneumatic contact shoe (CS) method while nine well-trained athletes ran at 2.8, 3.3, 3.9, 4.4, 5.0, and 5.6 m s-1. Disconnection and reconnection of the IR beams marked the stance phase. The sampling rate was 500 Hz for both methods. The stance phase duration was on average 11.5 (±8.4) ms longer with the IR40 than with the CS depending on earlier touch down (8.3 ± 6.2 ms) and delayed toe off (3.2 ± 5.3 ms) registrations. Significantly different stance phases were recorded between all velocities and for both methods. Thus, despite the fact that the IR40 systematically measured a somewhat longer stance phase duration than CS, the IR40 is nonetheless useful for temporal stride analysis during treadmill running.
© Copyright 2009 Sports Engineering. The Faculty of Health & Wellbeing, Sheffield Hallam University. Alle Rechte vorbehalten.

Bibliographische Detailangaben
Schlagworte:
Notationen:Naturwissenschaften und Technik Ausdauersportarten
Tagging:Infrarotmessung
Veröffentlicht in:Sports Engineering
Sprache:Englisch
Veröffentlicht: 2009
Online-Zugang:https://doi.org/10.1007/s12283-009-0021-8
Jahrgang:11
Heft:4
Seiten:195-200
Dokumentenarten:Artikel
Level:hoch