Unobtrusive and wearable landing momentum estimation in ski jumping with inertial-magnetic sensors

(Unauffällige und tragbare Landeimpulsschätzung im Skispringen mit inertial-magnetischen Sensoren)

An unobtrusive and low-cost landing analysis could not only support sports science research and ski jumping training but also decrease the risk of overuse and injuries. Although ski jumping biomechanics has been extensively researched, there is no known study on an unobtrusive analysis of the landing phase of actual ski jumps. In this work, we propose a landing momentum determination with inertial-magnetic measurement units (IMMUs) attached to the skis. We evaluate the calculated momenta against a mobile force plate and achieve accuracies of more than 90 % for three out of four jumps. Although the robustness of the measurement process can still be improved, our proposed algorithm builds the first step towards an IMMU-based landing analysis in ski jumping.
© Copyright 2018 IEEE 15th International Conference on Wearable and Implantable Body Sensor Networks (BSN), 2018. Veröffentlicht von IEEE Service Center. Alle Rechte vorbehalten.

Bibliographische Detailangaben
Schlagworte:
Notationen:Naturwissenschaften und Technik Kraft-Schnellkraft-Sportarten
Tagging:Kalibrierung
Veröffentlicht in:IEEE 15th International Conference on Wearable and Implantable Body Sensor Networks (BSN), 2018
Sprache:Englisch
Veröffentlicht: Las Vegas IEEE Service Center 2018
Online-Zugang:https://ieeexplore.ieee.org/document/8329669
Seiten:102-105
Dokumentenarten:Artikel
Level:hoch