An inexpensive solution for motion analysis

This study investigated the reliability of the recently released low-cost NaturalPoint OptiTrack 250e camera system across different measurement designs. Results are compared to an already well-established motion capture system from Vicon Motion Systems Ltd (Oxford, UK). The OptiTrack performed well across measurement conditions. Provided with the AMASS software kit from C-Motion (Germantown, MD, USA), nine distances from three rigid bodies (ten markers) were used to calculate measurement accuracy. Independent t-tests, a one-way multivariate analysis of variance, intra-class correlation coefficients, and the standard error of measurement were computed for all conditions to evaluate the differences and the reliability of the systems. The results suggest that the NaturalPoint OptiTrack 250e camera system is a reliable working system that can certainly be used in biomechanics and other related fields.
© Copyright 2014 Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology. SAGE Publications. All rights reserved.

Bibliographic Details
Subjects:
Notations:technical and natural sciences
Tagging:Kamera
Published in:Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology
Language:English
Published: 2014
Online Access:http://doi.org/10.1177/1754337114526868
Volume:228
Issue:3
Pages:165-170
Document types:article
Level:advanced