Comparison of tibial impact accelerations: video vs accelerometer

This study compared tibial axial accelerations measured by video analysis and accelerometry. Twenty-two recreationally active adults performed three countermovement jumps. The landing tibial axial accelerations were assessed with video and an accelerometer. High reliability was demonstrated for the root mean square error between the assessment methods (ICCave = 0.872). Repeated measures ANOVA results revealed no instrumentation differences in the magnitude of the two acceleration peaks (toe and heel contact) and no difference between trials. However, first and second peaks occurred 9.6 and 4.0 ms earlier, respectively, when assessed by video. Accelerometry is a valid and reliable alternative to video analysis for the assessment of tibial impact accelerations if temporal characteristics are not of interest.
© Copyright 2011 ISBS - Conference Proceedings Archive (Konstanz). Springer. Published by International Society of Biomechanics in Sports. All rights reserved.

Bibliographic Details
Subjects:
Notations:training science biological and medical sciences
Published in:ISBS - Conference Proceedings Archive (Konstanz)
Language:English
Published: Porto International Society of Biomechanics in Sports 2011
Online Access:http://w4.ub.uni-konstanz.de/cpa/article/view/4908
Volume:29
Issue:1
Pages:609-612
Document types:electronical journal
Level:advanced