Validity, reliability, and usefulness of jump performance from a low-cost contact mat
The purpose of this study was to establish the validity, reliability, and usefulness of a low-cost contact mat equipment (CM) with a force plate (FP) as the reference. Eleven female (18.6 ± 3.67 yrs.) and male (18.2 ± 2.71 yrs.) basketball athletes performed hands-on-waist countermovement jump (CMJ) and squat jump (SJ) trials. Flight time (FT) and jump height (JH) in CMJ and SJ were subjected for analysis. Relative error expressed as percentage (%RE) was utilized to examine criterion validity between CM and FP. Concurrent validity was also established using Pearson moment correlation (r). Absolute reliability was determined using coefficient of variation (%CV). Relative reliability was identified using intra-class correlation coefficient (ICC). Usefulness was established by comparing typical error (TE) vs. smallest worthwhile change (SWC). Results revealed that CMJ and SJ from a low-cost CM can be used as an alternative tool in assessment of jump performance.
© Copyright 2022 Journal of Human Sport & Exercise. University of Alicante. All rights reserved.
| Subjects: | |
|---|---|
| Notations: | sport games technical and natural sciences |
| Tagging: | Countermovement-Sprung Validität Reliabilität |
| Published in: | Journal of Human Sport & Exercise |
| Language: | English |
| Published: |
2022
|
| Online Access: | https://doi.org/10.14198/jhse.2022.172.03 |
| Volume: | 17 |
| Issue: | 2 |
| Pages: | 261-271 |
| Document types: | article |
| Level: | advanced |