Reliability of the high-speed camera-based system (HSC-Kinovea) for lower-limb explosive strength endurance assessment in athletes

The present study verified the reliability of the high-speed camera-based system (HSC-Kinovea) in the lower-limb explosive strength endurance assessment in athletes. Eleven male volleyball players (21.8 ± 2.9 years; 186.3 ± 6.2 cm and 82.3 ± 11.0 kg) participated in the intermittent vertical jumping test in two days. The test was filmed and later analyzed using Kinovea 0.8.15 software to obtain the mean and peak power variables. Regarding reliability, the intra-class correlation coefficient, the typical error of measurements, and Bland-Altman plots were used. The method presented satisfactory values for inter and intra-class correlations (? 0.88). The typical values error of measurement presented in the inter-rater analysis was 0.95 W.kg-1 and 0.59 W.kg-1 for the peak and the mean power, respectively. In the intra-assessment analyses, the typical measurement error values were 7.02 W.kg-1 and 5.66 W.kg-1 (test-retest) and 1.59 W.kg-1 and 0.24 W.kg-1 (duplicates videos) for peak and average power, respectively. The HSC-Kinovea system is reliable for assessing the variables of the explosive strength endurance in athletes.
© Copyright 2020 Journal of Physical Education. Departamento de Educação Física da Universidade Estadual de Maringá-UEM. All rights reserved.

Bibliographic Details
Subjects:
Notations:sport games technical and natural sciences
Published in:Journal of Physical Education
Language:English Portuguese
Published: 2020
Online Access:http://www.periodicos.uem.br/ojs/index.php/RevEducFis/article/view/48797
Volume:1
Issue:32
Pages:e3220
Document types:article
Level:advanced