Unsupervised gait event identification with a single wearable accelerometer and/or gyroscope: a comparison of methods across running speeds, surfaces, and foot strike patterns

We evaluated 18 methods capable of identifying initial contact (IC) and terminal contact (TC) gait events during human running using data from a single wearable sensor on the shank or sacrum. We adapted or created code to automatically execute each method, then applied it to identify gait events from 74 runners across different foot strike angles, surfaces, and speeds. To quantify error, estimated gait events were compared to ground truth events from a time-synchronized force plate. Based on our findings, to identify gait events with a wearable on the shank, we recommend the Purcell or Fadillioglu method for IC (biases +17.4 and -24.3 ms; LOAs -96.8 to +131.6 and -137.0 to +88.4 ms) and the Purcell method for TC (bias +3.5 ms; LOAs -143.9 to +150.9 ms). To identify gait events with a wearable on the sacrum, we recommend the Auvinet or Reenalda method for IC (biases -30.4 and +29.0 ms; LOAs -149.2 to +88.5 and -83.3 to +141.3 ms) and the Auvinet method for TC (bias -2.8 ms; LOAs -152.7 to +147.2 ms). Finally, to identify the foot in contact with the ground when using a wearable on the sacrum, we recommend the Lee method (81.9% accuracy).
© Copyright 2023 Sensors. All rights reserved.

Bibliographic Details
Subjects:
Notations:technical and natural sciences
Tagging:Ganganalyse Monitoring Gyroskop
Published in:Sensors
Language:English
Published: 2023
Online Access:https://doi.org/10.3390/s23115022
Volume:23
Issue:11
Pages:5022
Document types:article
Level:advanced