Estimating step parameters using photoelectric cells

The purpose of this study was to assess the OptoJumpTM photocell system (Microgate, Bolzano, Italy) in measuring step length and ground contact time during running. In two separate investigations, eight individuals repeatedly ran through a three metre section of OptoJumpTM track. Ground contact times were compared to concurrent force platform measures whereas step lengths were compared to physically measured lengths from foot imprints left in powder. Estimates of step length showed excellent validity with only 0.4% difference between methods and an intraclass correlation coefficient of 0.999. The OptoJumpTM systematically overestimated contact time with a mean bias of 2.7% compared to force platform measures. These results suggest that the OptoJumpTM can be effectively used to estimate step characteristics in real time.
© Copyright 2015 ISBS - Conference Proceedings Archive (Konstanz). Springer. Published by International Society of Biomechanics in Sports. All rights reserved.

Bibliographic Details
Subjects:
Notations:biological and medical sciences technical and natural sciences
Published in:ISBS - Conference Proceedings Archive (Konstanz)
Language:English
Published: Poitiers International Society of Biomechanics in Sports 2015
Online Access:https://ojs.ub.uni-konstanz.de/cpa/article/view/6469
Volume:33
Issue:1
Pages:604-607
Document types:congress proceedings
Level:advanced