A new device for estimating active drag in swimming at maximal velocity
A new device was designed to measure the active drag during maximal velocity swimming based on the assumption of equal useful power output in two cases: with and without a small additional drag. A gliding block was used to provide an adjustable drag, which was attached to the swimmer and measured by a force transducer. Six swimmers of national standard (3 males, 3 females) participated in the test. For the males, the mean active drag ranged from 48.57 to 105.88 N in the front crawl and from 54.14 to 76.37 N in the breaststroke. For the females, the mean active drag ranged from 36.31 to 50.27 N in the front crawl and from 36.25 to 77.01 N in the breaststroke. During testing, the swimmer's natural stroke and kick were not disturbed. We conclude that the device provides a useful method for measuring and studying active drag.
© Copyright 2007 Journal of Sports Sciences. Taylor & Francis. All rights reserved.
| Subjects: | |
|---|---|
| Notations: | endurance sports technical and natural sciences |
| Published in: | Journal of Sports Sciences |
| Language: | English |
| Published: |
2007
|
| Online Access: | https://doi.org/10.1080/02640410600812021 |
| Volume: | 25 |
| Issue: | 4 |
| Pages: | 375-379 |
| Document types: | article |
| Level: | advanced |