The rotor pedaling system improves anaerobic but not aerobic cycling performance in professional cyclists

The aims of this study were to evaluate the effects of both noncircular (ROT) and conventional (CON) chainring systems on aerobic and anaerobic cycling performances of professional cyclists, while analyzing the influence of varying the crank angle of maximum crank arm length of ROT. Fifteen professional road cyclists performed both incremental and sub-maximal aerobic tests and the Wingate anaerobic test in the laboratory. There were no statistical differences between CON and ROT in the aerobic tests, even when the best ROT position (ROT+) was selected. However, in the anaerobic test, maximal (4.2-9.1%) and mean (0.7-4.7%) power outputs were higher in ROT (P < 0.05). These differences were greater when the ROT+ was selected (11.2 and 7.0%, respectively). Our findings suggest that ROT is able to improve anaerobic but not aerobic cycling performance in professional cyclists. Nevertheless, it must be adapted to each cyclist to ensure these improvements.
© Copyright 2009 European Journal of Applied Physiology. Springer. All rights reserved.

Bibliographic Details
Subjects:
Notations:endurance sports
Published in:European Journal of Applied Physiology
Language:English
Published: 2009
Online Access:http://www.springerlink.com/content/n0614161313574l7/
Volume:106
Issue:1
Pages:87-94
Document types:article
Level:advanced