Intra- and inter-rater reliability of a video-based method to quantify stroke synchronisation in crew-boat sprint kayaking

(Intra- und Interratenzuverlässigkeit eines videobasierten Verfahrens zur Quantifizierung der Schlagsynchronisation im Kanusprint-Mannschaftsboot)

The purpose of this study was to assess the reliability of a method to quantify stroke synchronisation in crew-boat sprint kayaking from video analysis. One sub-elite K2 crew was recorded from a sagittal view at 120 Hz during a 200-m time trial. Video analysis identified the timing difference (termed "offset") between the front and back paddlers at four meaningful positions of the stroke (catch, immersion, extraction and release), with zero offset indicating perfect synchronisation. The anlaysis was performed twice by the same rater, as well as independently by two other raters. Results showed almost perfect intra-rater reliability, where intra-class correlation coefficients (ICC) ranged from .87 to 1.00, and standard error of measurement (SEM) from 0 to 5 milliseconds (ms). Inter-rater reliability was substantial to almost perfect (ICC .72 - .94, SEM 2 - 6 ms).
© Copyright 2017 ISBS Proceedings Archive (Michigan). Northern Michigan University. Veröffentlicht von International Society of Biomechanics in Sports. Alle Rechte vorbehalten.

Bibliographische Detailangaben
Schlagworte:
Notationen:Naturwissenschaften und Technik Trainingswissenschaft Ausdauersportarten
Veröffentlicht in:ISBS Proceedings Archive (Michigan)
Sprache:Englisch
Veröffentlicht: Cologne International Society of Biomechanics in Sports 2017
Online-Zugang:https://commons.nmu.edu/isbs/vol35/iss1/123
Jahrgang:35
Heft:1
Seiten:392-395
Dokumentenarten:Kongressband, Tagungsbericht
Level:hoch