Sprint kayaking stroke rate reliability, variability and validity of the Digitrainer accelerometer compared to GoPro video measurement
Reliability, variability, and validity of stroke rate measured via a Digitrainer accelerometer and GoPro 60 Hz video camera were determined. Six elite New Zealand kayakers (three males, three females) performed three trials of 300-m sprints in a single kayak (K1) mounted with the Digitrainer and camera. Average individual within-trial reliability and between-trial reliability and variability were calculated using data from 40 strokes beginning at 200-m. Both Digitrainer and video showed good reliability (Mdiff% =5%; ES =0.6), and moderate variability (ICC <0.67; TE% <10%). There was good agreement between Digitrainer and video stroke rates (r=0.86, p=0.000), however the Digitrainer overestimated stroke rate by 4 ±5 spm. Both systems can assess relative change in stroke rate, however video should be used when valid stroke rates are required.
© Copyright 2012 ISBS - Conference Proceedings Archive (Konstanz). Springer. Published by International Society of Biomechanics in Sports. All rights reserved.
| Subjects: | |
|---|---|
| Notations: | technical and natural sciences endurance sports |
| Published in: | ISBS - Conference Proceedings Archive (Konstanz) |
| Language: | English |
| Published: |
Melbourne
International Society of Biomechanics in Sports
2012
|
| Online Access: | https://ojs.ub.uni-konstanz.de/cpa/article/view/5294 |
| Volume: | 30 |
| Issue: | 1 |
| Pages: | 316-319 |
| Document types: | congress proceedings |
| Level: | advanced |