Comparison of the reliability of peak force measured during an isometric mid-thigh pull and isometric squat

The purpose of this study was to compare peak force produced during the isometric midthigh pull (IMTP) and isometric squat (IsoSquat), performed at the same knee and hip angles (135 - 140°) and determine the reliability of both tests. Following a specific warmup, 22 international athletes from different sports performed 2 maximal effort tests of both the IMTP and IsoSquat. Peak force achieved during the IsoSquat was significantly greater (p = 0.01) than peak force achieved during the IMTP. Both tests were highly reliable for peak force. Therefore, strength and conditioning coaches can select either test when examining lower extremity maximum strength. However, the IsoSquat produces higher peak force values and this may be a more accurate reflection of the athlete`s maximum strength.
© Copyright 2017 ISBS Proceedings Archive (Michigan). Northern Michigan University. Published by International Society of Biomechanics in Sports. All rights reserved.

Bibliographic Details
Subjects:
Notations:technical and natural sciences biological and medical sciences training science
Tagging:Kniebeuge
Published in:ISBS Proceedings Archive (Michigan)
Language:English
Published: Cologne International Society of Biomechanics in Sports 2017
Online Access:https://commons.nmu.edu/isbs/vol35/iss1/116
Volume:35
Issue:1
Pages:516-519
Document types:congress proceedings
Level:advanced